3. To validate the Belt Module is installed properly, gently close the Fuser Top Cover. If
it closes completely, the module is installed correctly. If it does not close, try to reinstall
the Fuser Belt Module again. Leave the Top Cover open.
4. Replace the wire bundle into the harness clip. Reconnect the three white connectors
at the front of the Fuser by pushing into place.
5. Push the black connector in until it clicks into place.
Note
The three white connectors are keyed and cannot be mixed up. The smallest connector
is in the back and the largest is in the front.
Note
Notice that the small white connector with the two black wires does not need to be
connected for this configuration.
6. Gently close the Fuser Top Cover. Reinstall the two larger screws using the T15 Torx
driver.
Note
You must reinstall the Front Fuser Cover.
7. Replace and secure the Fuser Front Cover with the smaller T10 screw.
Warning
You must push the drawer in. Pulling the drawer further out will disengage it from
the rails resulting in damage to the drawer and possible personal injury.
8. To push in and close the Transfer Drawer, press the rail tabs on each side of the
drawer with your fingers as you gently push the drawer into the press.
9. Latch the Transfer Drawer and close the Front Covers to complete the procedure.
10. Ask the administrator to reset the HFSI count for this newly-replaced CRU component.
The HFSI components that need to be reset at the press touch screen are:
Belt Module 1 (No Fuser connector)
Belt Module 2 (Fuser connector 1)