KCU105 Board User Guide www.xilinx.com 102
UG917 (v1.4) September 25, 2015
Appendix C: System Controller
VCCBRAM = 0.950 V
VCC1V8 = 1.800 V
VADJ1V8 = 1.800 V
VCC1V2 = 1.200 V
MGTAVCC = 1.000 V
MGTAVTT = 1.200 V
UTIL3V3 = 3.297 V
Option 2: Continuous Scan PMBUS Voltages
The list of voltages shown in option 1 is displayed and updated about once per second.
Pressing any key re-displays the PMBus menu.
Option 3: Get VCCINT Voltage
VCCINT = 0.950 V (one-time snapshot of the VCCINT voltage)
Unscaled Hex: MSB = 0x0F, LSB = 0x34
(The returned values include configuration setting details.)
Option 4: Get VCCAUX Voltage
VCCAUX = 1.800 V
Unscaled Hex: MSB = 0x1C, LSB = 0xCC
(The returned values include configuration setting details.)
Option 5: Get VCCBRAM Voltage
VCCBRAM = 0.950 V
Unscaled Hex: MSB = 0x0F, LSB = 0x33
(The returned values include configuration setting details.)
Option 6: Get VCC1V8 Voltage
VCC1V8 = 1.800 V
Unscaled Hex: MSB = 0x1C, LSB = 0xCC
(The returned values include configuration setting details.)
Option 7: Get VADJ1V8 Voltage
VADJ1V8 = 1.800 V
Unscaled Hex: MSB = 0x1C, LSB = 0xCB
(The returned values include configuration setting details.)