EasyManuals Logo

XP DEUS II User Manual

XP DEUS II
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
FACTORY PROGRAMS
GENERAL uses low and high frequencies and gives an excellent assessment of targets in the soil. It suits
both beginners and experienced users.
It offers an excellent target/false signal ratio in the ground, as it rejects the moisture in the soils, which can
cause halos and false sounds when passing over holes, for example. You will therefore have more con-
dence on deep targets. This damp / wet soil subtraction thus attenuates the very low electric conductors
like coke (coal, and conductive stone) and to a lesser extent certain very thin targets like aluminum foil.
• Very effective, test it in the soil, not in the air.
• Set the Reactivity to 2 for more efciency in cleaner soil or to 3 for polluted/mineralized soil.
has the advantage of offering a wide range of programs suitable for all ground and search condi-
tions. Unlike some multi-frequency detectors that offer xed multiple frequencies, uses different
high and low frequency combinations depending on the programs. For example, some use low to medi-
um frequencies e.g. 4 to 14 kHz and other programs include higher frequencies up to 24 kHz or 40 kHz.
Program-specic signal processing is applied to these frequency combinations and to the ground in the
best possible way. These frequencies can then be subtracted to remove electrically-conductive soils or
added together to help locate a wider range of targets. The processing platform information used for each
program is displayed in the title bar. Read the data for each program carefully to get the most out of your
!
(See also the comparison table at the end of the manual to better understand the different parameters
each program has to offer).
SENSITIVE uses low and high frequencies up to about 40 kHz. Highly efcient on all targets, it will be very
effective in mineralized and polluted ground when searching for the smallest targets.
• Thanks to the high precision that the DEUS II carries, coke and humidity can be classied with higher
accuracy than with a mono-frequency metal detector. A very narrow notch zone is thus activated within
frequencies 23 to 25 (see Notch > Expert)
• Reduce the Reactivity to 2 for more efciency in cleaner ground or increase it to 3 for polluted or min-
eralized ground.
SENSITIVE FULL TONES is based on the same platform as Prg. 2 - SENSITIVE, but it is congured using
Full Tone audio mode, with Reactivity at 3 instead of 2.5. It offers a very rich and informative sound identi-
cation that requires a little more experience, as each target index generates a different tone in proportion
to conductivity (see Discri > Full Tones). Very efcient in highly-polluted ferrous and mineralized ground.
FAST is based on the same platform as Prg. 2 - SENSITIVE, but the audio is set to Pitch mode with Re-
activity at 3 instead of 2.5 and uses the square audio feature. These three settings combined allow the
machine to work fast in ferrous-polluted and mineralized ground.
PARK is adjusted for searching recreational areas such as, parks, dry sand beaches, etc., or sites that
are normally polluted.
• A notch is active from 23 to 36 to reject aluminum foil. Increase it if necessary.
• B.Caps is set to 5 to reject most rusty ferrous caps.
DEEP HIGH CONDUCTOR adds together very low and medium frequencies up to 14 kHz.
Designed to better locate good conductivity targets, it is ideal for clusters of coins whilst maintaining ex-
cellent sensitivity to isolated coins using its 14 kHz frequency.
• Ground Stability is set to 1 and soils above your setting will therefore sound to provide you with the
best performance for specic deep searches (see Ground). Adjust the Ground by Grabbing but If you are
experiencing too many false signals, adjust GND Stability at 2 to reject all the soils, ferrites and shocks.
Prg. 2 - SENSITIVE
FMF •
Max. freq.
40khz • Frequency addition
Prg. 3 - SENSI FT
FMF •
Max. freq.
40khz • Frequency addition
Prg. 4 - FAST
FMF •
Max. freq.
40khz • Frequency addition
Prg. 5 - PARK
FMF •
Max. freq.
24khz • Frequency addition
Prg. 6 - DEEP HC
FMF •
Max. freq.
14khz • Frequency addition
Prg. 1 - GENERAL
FMF •
Max. freq.
40khz • Conductive soil subtraction

Table of Contents

Other manuals for XP DEUS II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the XP DEUS II and is the answer not in the manual?

XP DEUS II Specifications

General IconGeneral
Battery LifeUp to 20 hours
WirelessYes
DiscriminationYes
Operating Frequency4 to 45 kHz
WaterproofYes (up to 20 meters)
DisplayLCD
Target IDYes
Ground BalanceAutomatic and manual
HeadphonesWireless headphones included
Search Modescustomizable
ConnectivityBluetooth
Weight750 grams (control unit and coil)