EasyManua.ls Logo

XP DEUS II - Menu - Frequency Programs; FMF Multi Frequency Programs; Mono-Frequency Program

XP DEUS II
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
FMF multi frequency programs
Mono-frequency program
4 kHz
8 kHz
12 to 20 kHz
30 to 45 kHz
Small coins with low conductivity and ne jewellery, gold nuggets on highly mineralized ground. Discrim-
inates (distinguishes) coke more easily with a precise target identication (~25). More unstable on wet
ground, non-magnetic.
General use, small coins. Coins of all sizes in moderately to highly mineralized ground.
Large, mainly ferrous and non-ferrous masses, coins grouped together or high conductivity coins.
General use. Coins and large masses, militaria. Medium and small targets in low-mineralized ground.
FREQUENCY
EXPERT
MENU
78
25.5 KHZ
T.ID G.ID
IRON VOLUME
REACTIVITY
I 3
I 2.5
90
FREQ SHIFT
SCAN
MENU
78
5
T.ID G.ID
IRON VOLUME
REACTIVITY
I 3
I 2.5
90
Manual : Press
-
or
+
to shift the frequencies and nd the quietest band.
Automatic : Press
SCAN
to start an automatic scan.
Press
-
or
+
to select one of the 7 main frequencies.
If you are experiencing too much interference:
Press
EXPERT
then shift the main frequency with
-
and
+
or start an automat-
ic frequency scan by pressing
SCAN
.
MENU
IRON DISCRIMINATION
CAPABILITY
LARGER
TARGET
SMALLER
TARGET
MEDIUM
TARGET
Type of target detected is largely de-
pendent on the frequency:
These graphics illustrate the sensi-
tivity and the ability to discriminate
ferrous items depending on the fre-
quency as well as the advantage of
multi-frequency programs as they
cover a wide spectrum of targets.
This is a simplied schematic dia-
gram that can vary depending on the
programs and ground conditions.
FMF
40 kHz
35 kHz
28 kHz
21 kHz
15 kHz
7 kHz
4 kHz

Table of Contents

Other manuals for XP DEUS II

Related product manuals