SonTek, a Xylem brand
RiverSurveyor S5/M9 System Manual (February 2013)
25
5.3.5. Recorder
The Recorder Menu is provided on the Systems Tab and provides a way of managing files
stored on the 8 GB memory card. You can download all or a selection of files by using the op-
tions presented in the Recorder window.
Download all files downloads all files from the recorder
Download selected filesallows you to select files using the tick box next to the file
name. Simply select the files to download and then click on Download selected files.
Format Recorder Clears the memory of the recorder by erasing all files.
Make sure that there is adequate memory available on the recorder prior to making a discharge
measurement. It is suggested to download files and format the recorder between measurement
sites. All files must be downloaded from the ADP for post-processing and data evaluation.
5.3.6.
Measurement Procedure
Now that the pre-measurement tests and initial site specific entries are complete, it’s time to un-
derstand the basic principles behind a discharge measurement. Basically, the total discharge is
the amount of water flow (or net flux) through a section and is computed from the mean water
velocity and the cross-sectional area of the measurement section.
5.3.7. Overview
A single moving boat measurement of discharge can be broken into three key components: the
Start Edge, the Transect and the End Edge. These components are shown in Figure 21 below:
Figure 21. Measurement Sections