BEFORE YOU OPERATE
YM Series Operation Manual 37
12/05
9. Check the rubber hose (Figure 12, (1))
connecting the reservoir to the coolant
tank / heat exchanger. Replace if
damaged.
Note: If the coolant runs low too often
or the coolant level in the
coolant tank drops without any
change in the level in the
reservoir, there may be water or
air leaks in the cooling system.
Consult authorized Yanmar
dealer or distributor.
CRANKING THE ENGINE
When the engine has not been used for a
long period of time, engine oil will not be
distributed to all of the operating parts.
Using the engine in this condition will lead
to seizure. After a long period of no use,
distribute engine oil to each part by
cranking. Perform in accordance with the
following procedures before beginning
operation.
1. Open seacock.
2. Open fuel cock.
3. Put remote control shift lever in
NEUTRAL. See Starting the Engine on
page 41.
4. Turn on the battery switch (if equipped).
5. Crank the engine.
1- Push the power switch on the
instrument panel and turn on the
power.
2- Operate the starter while pushing in
the emergency stop button
(Figure 13) on the back of the fuel
pump. This stops the fuel supply.
When you push the start switch on the
instrument panel while the emergency
button is pushed in, the starter operates
and the engine cranks.
Crank the engine 5 seconds.