X K 3 1 9 0C 602
8
[ AB]
[PL ]
A—selection of printing language
(0: English; 1: Chinese)
B—printing direction
(0: no reverse printing, 1: reverse printing)
Parameter B is only effective
for micro printer. As for
panel-installed micro printer,
selecting reverse printing is
easy for checking printing
result.
9
[ AB]
[Auto P]
A—automatic printing
(0: no print, 1: automatic print)
B—automatic data saving
(0: no saving, 1: saving weight, 2: saving
time and weight) see note 1
If parameter A is set as 1, the
quantitative scale will
automatically print the actual
discharge quantity each time
and the catchweigher will
print the weight of material
measured each time.
10
[******]
[Aout_W]
The corresponding weight at full
range of analog output
When this weight is reached, the indicator
will output analog value at full range.
This value can be larger than
the max. weighing value, but
the max. output value is the
corresponding value at max.
weighing. When this value is
smaller than the max.
weighing value, the full range
of analog output will remain
unchanged.
11
[******]
[Aout_0]
DA internal code (0-20000) at zero point
of analog output
(output 4-20mA signal about 12520;
Output 0-5V/0-10V is 0)
The zero point of calibration
analog output of this
parameter can be modified.
12
[******]
[Aout_F]
DA internal code (10000-65535) at full
range of analog output
(4-20mA output about 62590;
0-5V/0-10V output about 65200)
The full range value o
f
calibration analog output
of this parameter can be
modified.
13
[ ABC]
[type ]
Aworking mode of the indicator
(0: additive scale, 1: subtracting scale, 2:
self-control catchweigher, 3: external
control catchweigher)
Bparameters number (0-4)
Cweight unit
(0: mg, 1: g, 2: kg, 3: t)
External control
catchweigher mode: the
indicator will only measure
weight upon being activated
by external control signal;
Self-control catchweigher:
the indicator automatically
starts weighing when the
weight is larger than zero
zone value.
14
[ A]
[Print?]
A-whether to print parameter setting
(0: No: 1: Yes)