X K 3 1 9 0C 602
There is only English format for parameter print, with explanation as follows:
Content of print Explanation
Set NO. 0 Parameters No., corresponding to SET 1
parameter 13B
Ctrl: 000 Control setting, corresponding to SET 2
parameter 1
Pt : 00010 Preset cycling times, corresponding toSET 2
parameter 2
A1 : 003.000kg Batching value of material 1, corresponding to SET
2parameter 3
B1 : 000.500kg Quick feed lead of material 1, corresponding toSET
2parameter 4
C1 : 000.020kg Slow feed lead of material 1corresponding toSET
2parameter 5
D1 : 000.020kg Tolerance of material 1, corresponding toSET 2
parameter 6
A2 : 003.000kg Batching value of material 2, corresponding toSET
2parameter 7
B2 : 000.500kg Quick feed lead of material 2, corresponding toSET
2parameter 8
C2 : 000.020kg Slow feed lead of material 2, corresponding toSET
2parameter 9
D2 : 000.020kg Tolerance of material 2, corresponding toSET 2
parameter 10
0_Zone 000.010kg Zero area setting, corresponding to SET 2
parameter 11
T0 : 0.2 s Timing 0, corresponding toSET 2parameter 12
T1 : 0.2 s Timing 1, corresponding toSET 2parameter 13
T2 : 0.2 s Timing 2, corresponding toSET 2parameter 14
T3 : 0.2 s Timing 3, corresponding toSET 2parameter 15
T4 : 0.2 s Timing 4, corresponding toSET 2parameter 16
T5 : 0.2 s Timing 5, corresponding toSET 2parameter 17
T6 : 0.2 s Timing 6, corresponding toSET 2parameter 18
T7 : 0.2 s Timing 7, corresponding toSET 2parameter 19