5-36
18
Timer function input (Functions are set in b4-01 and b4-02 and the timer function
outputs are set in H1- and H2-).
Yes Yes Ye s 6 -93
19 PID control disable (ON: PID control disabled) Yes Yes Yes 6-97
1A Accel/Decel time 2 Yes Yes Yes 6-18
1B
Parameters write enable (ON: All parameters can be written-in. off: All parameters
other than frequency monitor are write protected).
Yes Yes Ye s
6-133
7-17
1C Trim control increase (ON: d4-02 frequency is added to analog frequency reference). Yes Yes Yes 6-73
1D
Trim control decrease (ON: d4-02 frequency is subtracted from analog frequency ref-
erence).
Yes Yes Ye s 6 -73
1E Analog frequency reference sample/hold Yes Yes Yes 6-74
20 to 2F
External fault (Desired settings possible)
Input Mode: NO contact/NC contact, Detection Mode: Normal/during run
Yes Yes Ye s 6 -76
30
PID control integral reset (reset when Reset Command is input or when stopped dur-
ing PID control)
Yes Yes Ye s 6 -97
31 PID control integral hold (ON: Hold) Yes Yes Yes 6-97
32 Multi-step speed reference 4 Yes Yes Yes -
34 PID soft starter Yes Yes Yes 6-97
35 PID input characteristics switch Yes Yes Yes 6-97
60 DC Injection Braking Command (ON: Performs DC injection braking) Yes Yes Yes 6-15
61 External Search Command 1 (ON: Speed search from maximum output frequency) Yes Yes No 6-60
62 External Search Command 2 (ON: Speed search from set frequency) Yes Yes No 6-60
63 Field Weakening Command (ON: Field weakening control set for d6-01 and d6-02) Yes No No -
64 External Speed Search Command 3 Yes Yes Yes -
67
Communications Test Mode (“Pass” is displayed when the communications test is
passed).
Yes Yes Ye s 6 -93
71 Speed/torque control change (ON: Torque control) No No Yes
6-109
6-114
72 Zero-Servo Command (ON: Zero-servo) No No Yes 6-123
77 Speed control (ASR) proportional gain switch (ON: C5-03) No No Yes 6-116
78 Polarity Reversing Command for external torque reference No No Yes 6-109
Set
Value
Function
Control
Methods
Page
V/f
Open
Loop
Vector
Flux
Vector