7-65
Setting
value
Control Method
Function
Setting
value
Flux
vector
Open
loop
Vector
V/f
w/
PG
V/f
Function
61
External speed search command 1: Maximum output frequency (ON: speed search)
f
×
f
×
62
External speed search command 2: Set frequency (ON: speed search) f
×
f
×
63
Energy-saving command (ON: Energy-saving control set for b8-01, b8-02)
f f
× ×
64
External speed search command 3
f f f f
65
KEB (deceleration at momentary power loss) command (NO contact)
f f f f
66
KEB (deceleration at momentary power loss) command (NO contact)
f f f f
71
Speed/torque control change (ON: Torque control)
× × ×
f
72
Zero-servo command (ON: Zero-servo)
× × ×
f
77
Speed control (ASR) proportional gain switch (ON: C5-03)
× × ×
f
Constant Settings
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit
Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
H1-01
Multi-function input
1 (terminal 3)
×
0to77 24
B B B B
H1-02
Multi-function input
2 (terminal 4)
×
0to77 14
B B B B
H1-03
Multi-function input
3 (terminal 5)
×
0to77 3 (0)
B B B B
H1-04
Multi-function input
4 (terminal 6)
×
0to77 4 (3)
B B B B
H1-05
Multi-function input
5 (terminal 7)
×
0to77 6 (4)
B B B B
H1-06
Multi-function input
5 (terminal 8)
×
0to77 8 (6)
B B B B
D
The factory settings in parentheses are for when the Unit is initialized for 3-wire control.
D
The following table shows the settings and section references for some common functions.
Function Setting Section
3-wire sequence (forward/reverse run command)
0 6.1.8
Multi-step speed references 1 to 3 and jog fre-
quency reference
3to6 6.1.8
Accel/Decel time 1 and 2
7, 1A 6.1.8
Emergency stop
15 6.1.8
FJOG/RJOG commands
12, 13 6.1.8
Terminal 13/14 switch
1F 6.1.8
Timer function input
18 7.5.1
Energy-saving command
63 7.2.1, 7.4.1
Local/Remote Selection (Setting: 1)
OFF
Operate with the frequency reference and run command specified in b1-01 (the frequency refer-
ence source) and b1-02 (run source).
ON
Operate with the frequency reference and run command set at the Digital Operator.
D
With this setting, the multi-function input selects the input method for the frequency reference and run
command.
D
The input method can be switched only when the Inverter is stopped.
D
The Digital Operator LOCAL/REMOTE Key is disabled when this function has been set in a multi-
function input.
7