User Constants
8.2.5 Options Constants: F
8-24
8.2.5 Options Constants: F
J
PG Option Setup: F1
Con-
Name
Change
Control Methods
stant
Num-
ber
Display
Description
Setting
Range
Factory
Setting
during
Opera-
tion
V/f
V/f
with
PG
Open
Loop
Vector
Flux
Vector
Page
PG constant
Sets the number of PG (pulse generator or
encoder) pulses.
0to
6-28
F1-01
PG Pulse/Rev
:Sets the number of pulses per motor rev-
olution.
60000
600
× ×
Q
×
Q
6-42
F1-02
Operation
selection at PG
open circuit
Sets the PG disconnection stopping method.
0: Ramp to stop (Deceleration stop using
deceleration time 1, C1-02.)
1: Coast to stop
2: Fast sto
Emer
enc
sto
usin
the
0to3 1
× ×
B
×
B
6-29
PG Fdbk Loss
Sel
fast-stop time, C1-09.)
3: Continue operation (To protect the mo-
tor or machinery, do not normally make
this setting.)
6-42
F1-03
Operation
selection at
overspeed
Sets the stopping method when an over-
speed (os) fault occurs.
0: Ramp to stop (Deceleration stop using
deceleration time 1, C1-02.)
1: Coast to stop
0to3 1
× ×
B
×
B
6-30
PG Overspeed
Sel
2: Fast stop (Emergency stop using the
fast-stop time, C1-09.)
3: Continue operation (To protect the mo-
tor or machinery, do not normally make
this setting.)
6-43
F1-04
Operation
selection at
deviation
Sets the stopping method when a speed
deviation (DEV) fault occurs.
0: Ramp to stop (Deceleration stop using
deceleration time 1, C1-02.)*1
1: Coast to stop*1
2: Fast stop (Emergency stop using the
fast-stop time, C1-09.)*1
3: Continue operation (DEV is displayed
and operation continued.)*1
4: Decleration to stop using deceleration
time1(c1−02)*2
5: Coast to stop*2
−
0to7 3
× ×
B
×
B
6-30
PG Deviation
Sel
:
mergency a
op us
ng
e emergency−
stop time (C1−09)*2
7: Continue Operation (Displays ”DEV”
and continues cntrol)*2
*1 Speed agreement conditions: The fre-
quency reference and output frequency
were entered in the speed agree detec-
tion width set in L4−02.
*2 Speed agreement conditions: The fre-
quency reference and the (actual) motor
speed based on the PG feedback value
were entered in the speed agree detec-
tion width set in L4−02.
6-43
PG rotation
0: Phase A leads with forward run com-
mand. (Phase B leads with reverse run
F1-05
PG Rotation
Sel
command.
1: Phase B leads with forward run com-
mand. (Phase A leads with reverse run
command.)
0, 1 0
× ×
B
×
B
6-28
F1-06
PG division
rate (PG pulse
monitor)
Sets the division ratio for the PG speed con-
trol card pulse output.
Division ratio = (1+ n) /m (n=0,1 m=1 to
32
)
F1−06 =
j jj
1 to 132 1
× ×
B
×
B
6-29
PG Output Ra-
tio
:This constant is only effective when a
PG-B2 is used.
The possible division ratio settings are:
1/32 ≤ F1-06 ≤ 1.
mn
8