8.2 Programming Mode Constants
8-47
8.2.10 Factory Settings that Change with the Inverter Capacity (o2-04)
J 200 V Class Inverters
Con-
stant
Number
Name Unit Factory Setting
Inverter Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11
o2-04 kVA selection --- 0 1 2 3 4 5 6 7
C6-01 Carrier frequency upper limit
kHz 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0
Carrier frequency upper limit
range
kHz 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0
C6-02 Carrier frequency lower limit
kHz 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0
C6-03
Carrier frequency proportional
gain
--- 0 0 0 0 0 0 0 0
E2-01
(E5-01)
Motor rated current
A 1.90 3.30 6.20 8.50 14.00 19.60 26.60 39.7
E2-02
(E5-02)
Motor rated slip
Hz 2.90 2.50 2.60 2.90 2.73 1.50 1.30 1.70
E2-03
(E5-03)
Motor no-load current
A 1.20 1.80 2.80 3.00 4.50 5.10 8.00 11.2
E2-05
(E5-05)
Motor line-to-line resistance
9.842 5.156 1.997 1.601 0.771 0.399 0.288 0.230
E2-06
(E5-06)
Motor leak inductance
% 18.2 13.8 18.5 18.4 19.6 18.2 15.5 19.5
E2-10
Motor iron loss for torque com-
pensation
W 14 26 53 77 112 172 262 245
L2-02
Momentary power loss ridethru
time
sec 0.7 1.0 1.0 1.0 2.0 2.0 2.0 2.0
L2-03 Min. baseblock time
sec 0.5 0.5 0.5 0.5 0.5 0.7 0.7 0.7
L2-04 Voltage recovery time
sec 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Con-
stant
Number
Name Unit Factory Setting
Inverter Capacity kW 15 18.5 22 30 37 45 55 75
o2-04 kVA selection --- 8 9 A B C D E F
C6-01 Carrier frequency upper limit
kHz 15.0 15.0 10.0 10.0 10.0 10.0 10.0 10.0
Carrier frequency upper limit
range
kHz 15.0 15.0 10.0 10.0 10.0 10.0 10.0 10.0
C6-02 Carrier frequency lower limit
kHz 15.0 15.0 10.0 10.0 10.0 10.0 10.0 10.0
C6-03
Carrier frequency proportional
gain
--- 0 0 0 0 0 0 0 0
E2-01
(E5-01)
Motor rated current
A 53.0 65.8 77.2 105.0 131.0 160.0 190.0 260.0
E2-02
(E5-02)
Motor rated slip
Hz 1.60 1.67 1.70 1.80 1.33 1.60 1.43 1.39
E2-03
(E5-03)
Motor no-load current
A 15.2 15.7 18.5 21.9 38.2 44.0 45.6 72.0
E2-05
(E5-05)
Motor line-to-line resistance
0.138 0.101 0.079 0.064 0.039 0.030 0.022 0.023
E2-06
(E5-06)
Motor leak inductance
% 17.2 20.1 19.5 20.8 18.8 20.2 20.5 20.0
E2-10
Motor iron loss for torque com-
pensation
W 272 505 538 699 823 852 960 1200
L2-02
Momentary power loss ridethru
time
sec 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0