6 Basic Operation
YASK AWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual 31
The following procedure is used to read parameters from the drive.
Note: Set parameter o3-02 (Read Allowable) to “1” (Enable) to read the parameter settings from the
drive.
Set parameter o3-02 to “0” (disable) to protect the parameter settings in the LCD Operator
Option.
Procedure LCD Screen
1. Frequency Reference display.
2. Press to select the Programming Mode.
3. Press to show the Initialization display.
4. Press to select o3-01 and press
.
5. Press to enter 1 (INV --> OP READ).
- MODE -
U1-01= 6.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
LSEQ
LREF
FREF (OPR)
Rdy
JOG FWD FWD/REV
HELP
-MODE- PRG
DATA
Programming
FWD
←→
-PRMSET-
Initialization
Select Language
PRG
FWD
A1-00=0
F1 F2
←→
-PRMSET-
Copy Funtion Sel
COPY SELECT
PRG
FWD
o3-01= 0 *0*
←→
-PRMSET-
Copy Funtion Sel
o3-01= 1 *0*
INVOP READ
PRG
FWD
0