6 Basic Operation
30 YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual
Read/Copy Function Procedure
Read
Reads and saves the parameter settings from the drive to the LCD Operator Option.
Note: The LCD Operator Option can perform the Read function an estimated 100,000 times.
Copy
Copies the parameter settings from the LCD Operator Option to another Yaskawa drive.
Verify
Verifies that parameter settings in the drive match the parameter settings saved to the LCD
Operator Option.
5. Press to enter 20.0 sec.
6. Press to enter and store the new setting for C1-01.
F1 F2
-PRMSET-
C1-01=0020.0Sec
(0.0~6000.0)
“10.0 sec”
PRG
Accel Time 1
←→
FWD
Entry Accepted