11.2 Safety Module
11.2.2 Specifications
11-11
11.2.2
Specifications
Basic Specifications
Compliance with UL Standards, EU Directives, and Other
Safety Standards (in Combination with SERVOPACK)
Safely Limit Speed
with Delay Function
(SLS-D function)
This safety function is equivalent
to an SLS function. (It monitors
the deceleration operation of the
motor for the specified time and
then monitors the speed of the
motor to confirm that it remains in
the allowable range.)
–
: Applicable
Continued from previous page.
Safety Function Description
Applicable Products
SERVOPACK
SERVOPACK +
Safety Module
Item Specification
Operating
Conditions
Surrounding Air
Temperature
0˚C to +55˚C
Storage Tempera-
ture
-20˚C to +85˚C
Surrounding Air
Humidity
90% relative humidity
max.
There must be no freezing or condensation.
Storage Humidity
90% relative humidity
max.
Vibration Resistance
4.9 m/s
2
Shock Resistance
19.6 m/s
2
Degree of Protection IP10 • Must be no corrosive or flammable gases.
• Must be no exposure to water, oil, or chemi-
cals.
• Must be no dust, salts, or iron dust.
Pollution Degree 2
Altitude 1000 m max.
Others
Do not use the SERVOPACK in the following locations:
Locations subject to static electricity noise, strong electromagnetic/
magnetic fields, or radioactivity
Item Specification
North American Safety Standards (UL)
UL61800-5-1 (E147823),
CSA C22.2 No.274
EU
Directives
Machinery Directive
2006/42/EC
EN ISO13849-1: 2015
EMC Directive
2014/30/EU
EN 55011 group1 classA
EN 61000-6-2
EN 61000-6-4
EN 61800-3 (Category C2, Second Environment)
Low Voltage Directive
2014/35/EU
EN 50178
EN 61800-5-1
RoHS Directive
2011/65/EU
EN 50581
Continued on next page.