The motor speed has exceeded the overspeed level
when operating in the Closed Loop V/f or Closed
Loop Flux Vector modes.
OS
Overspeed Det
N/A
Feedback pulses are not received by the PG option
board.
PGO
PG open
N/A
Possible Cause(s): The load has changed considerably, the program settings may not be
set correctly.
Corrective Action: Check the load on the motor, verify the program settings (F1-08 PG
Overspeed Level, and F1-09 PG Overspeed Time).
Possible Cause(s): The Pulse Generator feedback wires may be broken or not properly
connected to the PG feedback option board.
Corrective Action: Check for a broken wire or a loose connection from the Pulse
Generator, verify the program settings.