EasyManua.ls Logo

YASKAWA GPD 505/P5 - EF3 External Fault3; EF4~8 External Fault

YASKAWA GPD 505/P5
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PP.P5G5.03.Troubleshoot
Page 17
Rev. 06/11/2003
External fault at terminal number 3.
EF3
External Fault3
ef3
External fault at the multi-function inputs terminal
number 4 ~ 8. 506 is the same as 505 and only has
EF 4-6.
EF4~8
External Fault
ef4
~6
Possible Cause(s): An external fault condition exists connected to terminal number 3.
Corrective Action: Check for an external condition, verify the program parameters.
Possible Cause(s): An external fault condition exists connected to one of the terminals 4,
5, 6, 7, or 8.
Corrective Action: Check for an external condition, verify the program parameters.
505
Fault Codes
Major Fault - Motor coasts to a stop, the fault is displayed on the digital
operator, and the fault relay is activated.
506 515