EasyManua.ls Logo

YASKAWA GPD 505/P5 - CPF00 Com-Err(OP&INV); CPF01 Com-Err(OP&INV)

YASKAWA GPD 505/P5
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PP.P5G5.03.Troubleshoot
Page 20
Rev. 06/11/2003
CPF00
Com-Err(OP&INV)
Transmission between the inverter and the operator
cannot be established 5 seconds after supplying
power.
cpf0
Possible Cause(s): Digital operator cable not securely connected, digital operator
defective, control board defective.
Corrective Action: Check the operator cable, replace the digital operator, replace the
control board.
CPF01
Com-Err(OP&INV)
Communication fault between the inverter and the
operator has occurred for more than 2 seconds.
cpf1
Possible Cause(s): Digital operator cable not securely connected, digital operator
defective, control board defective.
Corrective Action: Check the digital operator cable, replace the digital operator, replace
the control board.
505
Fault Codes
Major Fault - Motor coasts to a stop, the fault is displayed on the digital
operator, and the fault relay is activated.
506 515