The CPU on the SI-F/G option board has stopped
operating.
E-10
SI-F/G CPU down
Possible Cause(s): Defective option board, electrical noise effecting operation.
Corrective Action: Cycle power, replace the option board.
Possible Cause(s): Connection is broken, master has stopped communicating.
Corrective Action: Check all connections, verify all user side software configurations.
E-15
SI-F/G Com Err
After initial communication has been established, the
connection was then lost.
Response may be selected.
505
N/A
N/A
Fault Codes
Major Fault - Motor coasts to a stop, the fault is displayed on the digital
operator, and the fault relay is activated.
♣ E-10 and E-15 fault codes may only appear when using the OMRON specification (O2-09=3).
♣
♣