PP.P5G5.03.Troubleshoot
Page 28
Rev. 06/11/2003
ol3
Over torque detection function.
A customer programmable current detection. Response
may be selected. A minor fault contact output can be
programmed by using the multi-function outputs.
OL3
Overtorque Det 1
OL4
Overtorque Det 2
N/A
Over torque detection function (2).
A customer programmable current detection. Response
may be selected. A minor fault contact output can be
programmed by using the multi-function outputs.
Possible Cause(s): Motor is overloaded.
Corrective Action: Verify the program settings, reduce the load on the motor.
Possible Cause(s): Motor is overloaded.
Corrective Action: Verify the program settings, reduce the load on the motor.
F
ault Codes
Minor Fault - Operation continues and the digital operator indication blinks
The fault relay does not activate.
505
506 515
505
506 515

Table of Contents