EasyManua.ls Logo

YASKAWA SGDV-180A - Mach4 Setup

YASKAWA SGDV-180A
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Calculate the value of Pn552 based on the max rated torque you will ever see on this device:
Pn552 = 10V / (0.01 * Max Rated Torque %)
Max Rated
Torque %
Pn552
40%
25.00
50%
20.00
100%
10.00
300%
03.33
For example, if you want to see up to 50% of rated torque, calculate it as follows:
Pn552 = 10V / (0.01 * 50%) = 20.00 so you would set Pn552 to 20.00.
Proof:
Actual Output Voltage = Pn552*0.01 * Actual Rated Torque %
Substitute Max Output Voltage for Actual Output Voltage and Max Torque for Actual Rated Torque:
Max Output Voltage = Pn552*0.01 * Max Rated Torque %
Solve for Pn552:
Pn552 = Max Output Voltage / (0.01 * Max Rated Torque %)
Set Max Output Voltage to 10V:
Pn552 = 10V / (0.01 * Max Rated Torque %)
If using the Siemens PLC, see this document: Siemens PLC - Wiring SM1234.
Reference Manual: See attached Sigma-7 Manual Analog-Pulse.pdf
Keywords: Load meter, spindle load
Mach4 Setup

Table of Contents