A.100
Overheated
(An
overcurrent
flowed
through
the IGBT
or heat
sink of
SERVOPACK
overheated.)
Short-circuit or ground fault
of main circuit cable or
servomotor main circuit
cable.
across the servomotor
terminal phases U, V,
and W, or between the
grounding and
servomotor terminal
phases U, V, or W.
Short-circuit or ground fault
inside the servomotor.
Check for short-circuits
across the servomotor
terminal phases U, V,
and W, or between the
grounding and
servomotor terminal
phases U, V, or W.
A.100
(cont.)
Overcurrent
or Heat
Sink
Overheated
(An
overcurrent
flowed
through
the IGBT
or heat
sink of
SERVOPACK
overheated.)
Short-circuit or ground fault
inside the SERVOPACK.
Check for short-circuits
across the servomotor
connection terminals
U, V, and W on the
SERVOPACK, or
between the grounding
and terminal U, V, or
W.
Incorrect wiring or contact
fault of the regenerative
resistor.
Check the wiring.
The dynamic brake (DB:
Emergency stop executed
from the SERVOPACK) was
frequently activated, or the
DB overload alarm
occurred.
Check the power
consumed by DB
resistance (Un00B) to
see how many times
the DB has been used.
Or, check the alarm
history display Fn000
to see if the DB
overload alarm A.730
or A.731 was reported.
The generated regenerative
resistor value exceeded the
SERVOPACK regenerative
energy processing capacity.
Check the regenerative
load ratio (Un00A) to
see how many times
the regenerative
resistor has been used.
The SERVOPACK
regenerative resistance is
too small.
Check the regenerative
load ratio (Un00A) to
see how many times
the regenerative
resistor has been used.
A heavy load was applied
while the servomotor was
stopped or running at a low
speed.
Check to see if the
operating conditions
are outside servo drive
specifications.
Malfunction caused by noise
interference.
Improve the wiring or
installation
environment, such as
by reducing noise, and
check to see if the
alarm recurs.
A SERVOPACK fault
occurred.
--
- Regenerative resistor
capacity (Pn600) is set to a
value other than 0 for a
SGDV-R70, -R90, -1R6, -2R1,
or -2R8 SERVOPACK, and an
external regenerative
resistor is not connected.
- An external regenerative
resistor is not connected to
Check the external
regenerative resistor
connection and the
value of the Pn600.