6 Wiring
6.5.2 Connecting External Regenerative Resistors
6-32
(2) Specifications of Built-in Regenerative Resistor
If the amount of regenerative energy exceeds the processing capacity of the SERVOPACK, then install an exter-
nal regenerative resistor. The following table shows the specifications of the SERVOPACK’s built-in resistor and
the amount of regenerative power (average values) that it can process.
* 1. The average regenerative power that can be handled is 20% of the rated capacity of the regenerative
resistor built into the SERVOPACK.
* 2. The values in parentheses are for the optional JUSP-RA04 Regenerative Resistor Unit.
* 3. The values in parentheses are for the optional JUSP-RA05 Regenerative Resistor Unit.
Applicable SERVOPACKs
SGDM-
Specifications
of Build-in Resistor
Regenerative Power
Processed by Built-in
Resistor
1
(W)
Minimum
Allowable
Resistance
()
Resistance
()
Capacity
(W)
Single-phase
100 V
A3BD to -02BD,
A3BDA to -02BDA
−− 40
Single-phase
200 V
A3AD to -04AD,
A3ADA to -04ADA
−− 40
Three-phase
200 V
05AD to -10AD,
05ADA to -10ADA
50 60 12 40
15AD, 15ADA
30 70 14 20
20AD, 20ADA
25 140 28 12
30AD, 30ADA
12.5 140 28 12
50ADA
8 280 56 8
60ADA
(6.25)
2
(880)
2
(180)
2
5.8
75ADA to -1EADA
(3.13)
3
(1760)
3
(350)
3
2.9