8
EMC Installation Conditions
42
Three-Phase, 400 VAC
CN2
CN6A and CN6B
L1, L2, and L3
U, V, and W
Noise
Filter
Surge
Absorber
Clamp
Brake
Servomotor
Encoder
Brake power supply
SERVOPACK
Safety
function device
I/O
controller
PE
PE
Shield box
Power supply:
Three-phase, 400 VAC
ClampClamp
Clamp
Clamp
Clamp
Clamp

Host controller
Clamp
CN1
24 V, 0 V
Power supply:
24 VDC
CN8
Symbol Cable Name Specification
I/O Signal Cable Shielded cable
Safety Function Device Cable Shielded cable
Servomotor Main Circuit Cable Shielded cable
Encoder Cable Shielded cable
Main Circuit Power Supply Cable Shielded cable
Ethernet Communications Cable Shielded cable