User Constants
7.1.5 Motion-related Constants
Time
Cn-0021: Acceleration/Deceleration Constant Switching Speed
Sets the speed for switching front the first—step to the second—step acceleration/deceleration
in two-step acceleration/deceleration.
Allowable setting range: 0 to 65535 [ x 100 reference units/s]
Cn-0026: Running Average Time
Sets the time of running average for S-curve acceleration/deceleration.
This constant is used for S-curve acceleration/deceleration.
Allowable setting range: 0 to 5100 [ x 100 j.ts]
Running average is not valid when "0" is set.
Cn-002D: Exponential Acceleration/Deceleration Bias
Sets bias to change linear acceleration/deceleration to exponential acceleration/deceleration.
Allowable setting range: 0 to 32767 [ x 500 reference units/s]
Cn-002E: Exponential Acceleration/Deceleration Time Constant
Sets the time constant to change linear acceleration/deceleration to exponential acceleration/
deceleration.
Allowable setting range: 0 to 5100 x 100 las]
Exponential acceleration/deceleration is not valid when "0" is set.
Cn-0022: Zero Point Return Approach Speed 1
Sets the approach speed for returning to the zero point after the deceleration limit switch sig-
nal turns ON.
Allowable setting range: 0 to 65535 [ x 100 reference units/s]
Cn-0023: Zero Point Return Approach Speed 2
Sets the speed to search for the zero point after the deceleration limit switch signal turns ON
or OFF.
7 -6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SMG Series and is the answer not in the manual?

YASKAWA SMG Series Specifications

General IconGeneral
BrandYASKAWA
ModelSMG Series
CategoryController
LanguageEnglish

Related product manuals