WARNING! Crush Hazard. Use an adequate length of wire to ensure a 50° or wider suspension angle as illustrated in Figure i.12. The
maximum allowable load of the eye bolts cannot be guaranteed when the drive or harmonic filter module is suspended with the wires at
angles less than 50°. Failure to comply may result in serious injury or death from falling equipment.
1. Pass wire through the holes of the two eye bolts.
Suspending angle:
50° or greater
Figure i.12 Suspension Using Wires and Eye Bolts
2. Gradually take up the slack in the wires and hoist the drive or harmonic filter module after the wires are stretched tight.
3. Lower the
drive or harmonic filter module when ready to install in the enclosure panel. Stop lowering when near the floor,
then slowly begin lowering the drive or harmonic filter module again until the drive or harmonic filter module is placed
correctly.
Drive Models 2
o
0154 to 2
o
0248 and 4
o
0156 to 4
o
0414
WARNING! Crush Hazard. Use an adequate length of wire to ensure a 50° or wider suspension angle as illustrated in Figure i.13. The
maximum allowable load of the eye bolts cannot be guaranteed when the drive is suspended with the wires at angles less than 50°. Failure
to comply may result in serious injury or death from falling equipment.
1. Remove the two hanging brackets from the drive lower side panels and bolt them on the top panel.
Note: 1. Tighten the hanging brackets with the specified tightening torque: M10: 18 to 23 N·m (159 to 204 in-lb),
M12: 32 to 40 N·m (283 to 354 in-lb).
2.
Four hanging brackets are attached to the top of IP20/NEMA 1, UL Type 1 drives 2o0154F, 2o0192F, 4o0156F, and 4o0180F.
Figure i.13 Location of Hanging Brackets (Drive Models 2o0154 to 2o0248 and 4o0156 to 4o0414)
2. Pass wire through the holes of all four hanging brackets.
i.3 Mechanical Installation
22