General Instruction Manual
Installation
Transmitter installation
36 / 90
IM 01U10B00-00EN-R, 3rd edition, 2018-07-09
6.5.2 Rotating transmitter housing (integral type)
The transmitter housing can be installed in any one of four orientations.
WARNING
Short-circuit hazard caused by penetrating water
Failure of measuring electronics
In order to prevent any water from penetrating the flow meter by way of the cable,
install the transmitter in a way so that the cable gland is not pointed upward.
WARNING
Insufficient sensor grounding connection
Electric shock and ignition in hazardous areas
Use a minimum torque of 4.3 Nm when tightening the screws.
NOTICE
Damage to flow meter
Rotating the transmitter housing several times in the same direction may damage the
connection between sensor and transmitter.
Do not turn transmitter housing more than 270° in the same direction.
1. By using an Allen wrench (size: 5.0), remove the four fixing screws.
2. Lift transmitter housing.

Table of Contents

Other manuals for YOKOGAWA ROTAMASS Total Insight

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA ROTAMASS Total Insight and is the answer not in the manual?

YOKOGAWA ROTAMASS Total Insight Specifications

General IconGeneral
BrandYOKOGAWA
ModelROTAMASS Total Insight
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals