JOHNSON CONTROLS
8
FORM 100.50-NOM7 (808)
ACRONYM CHART
  ACRONYM TEXT
  APS  Air Proving Switch
  ASCD  Anti-Short Cycle Delay
  AQ  Air Quality (CO
2
)
  BS  Building Static
  COR  Cooling / Heating Changeover Relay
  CP1 – CP3  Condensing Pressure Circuit 1 Through 3
  CS1 – CS3  Compressor Circuit 1 Through 3
  CV  Constant Volume
  DFS  Dirty Filter Switch
  DS  Duct Static Pressure
  DVM  Demand Ventilation Multiplier
  EAD  Exhaust Air Damper
  EC Economizer
  EDAT  Evaporator Discharge Air Temperature
  EF  Exhaust Fan
  ESTOP  Emergency Stop
  FS  Freeze Stat (HW/Steam)
  G  Thermostat Input for the Fan
  HW  Hot Water
  MIT  Modular Integrated Terminal 
  MITD  MIT Bypass Damper
  OA  Outdoor Air
  OAD  Outside Air Damper
  OAT  Outside Air Temperature
  ACRONYM TEXT
  OAH  Outside Air Humidity
  OCC Occupied
  P Purge
  PE  Power Exhaust Output
  RA  Return Air
  RAT  Return Air Temperature
  RAH  Return Air Humidity
  RDU  Remote Display Unit
  SAT  Supply Air Temperature
  SF  Supply Fan
  SS  Space Sensor
  SSA  Space Setpoint Adjust
  SMK  Smoke Purge
  SP1 – SP3  Suction Pressure Circuit 1 Through 3
  ST  Space Temperature
 STG1 – STG6  Cooling/Heating Stage 1 Through 6
  UNOCC Unoccupied
  VAV  Variable Air Volume
  VFD  Variable Frequency Drive
  W1  Thermostat Input For The First Stage of Heating
  W2  Thermostat Input For The Second Stage of Heating
  X  Alarm Output
  Y1  Thermostat Input For The First Stage of Cooling
  Y2  Thermostat Input For The Second Stage of Cooling
  YDC  YORK Digital Controller
LIST OF TABLES
TABLE 1 - 25 – 40-TON R410A COMPRESSOR LOGIC ..............................................................17
TABLE 2 – TIMEOUTS AND DELAYS ...........................................................................................19
TABLE 3 – MODES OF OPERATION .............................................................................................23
TABLE 4 – VAV MODES OF OPERATION .....................................................................................28
TABLE 5 – HISTORY FUNCTION TEXT (LINE 2) .........................................................................51
TABLE 6 – HISTORY POINTS DATA LIST ....................................................................................51
TABLE 7 – SETPOINTS AND VALUES .........................................................................................62
TABLE 8 – TEMPERATURE SENSOR RESISTANCE TABLE ....................................................71
TABLE 9 – *DUCT PRESSURE TRANSDUCER OUTPUT TABLE .............................................71
TABLE 10 – BUILDING PRESSURE TRANSDUCER OUTPUT TABLE .....................................72
TABLE 11 – HUMIDITY SENSOR OUTPUT...................................................................................73
TABLE 12 – CO
2
 SENSOR OUTPUT ..............................................................................................73
TABLE 13 –  THERMOSTAT INTERFACE BOARD VOLTAGE OUTPUTS .................................74
TABLE 14 – THERMOSTAT INTERFACE BOARD CONNECTIONS ..........................................75
TABLE 15 – INPUT/OUTPUT TABLE .............................................................................................76
TABLE 16 – MONITOR AND CONTROL I/O FROM MOD-DCU ..................................................78
TABLE 19 - FAULT DESCRIPTIONS TABLE ................................................................................79