TABLE 21 - YORKTALK 2 COMMUNICATIONS DATA MAP (CONT’D)
Address Scale
Imperial SI
Point List Description
1
2
3
4
5
6
7
8
9
10
P48
BV117
YT2_ S02_ P48
nvoYTS02p048
SNVT_switch (95)
BD 46
0177
N/A
0/1
0/1
YCWL Mode [0=Chiller, 1=Heatpump]
N
O
O
O
O
P49
BV118
YT2_ S02_ P49
nvoYTS02p049
SNVT_switch (95)
BD 47
0178
N
N
N
N
N
P50
BV119
YT2_ S02_ P50
nvoYTS02p050
SNVT_switch (95)
BD 48
0179
N/A
0/1
0/1
SCC Auto Detect Digit 1
N
S
S
S
S
P51
BV120
YT2_ S02_ P51
nvoYTS02p051
SNVT_switch (95)
BD 49
0180
N/A
0/1
0/1
SCC Auto Detect Digit 2
N
S
S
S
S
P52
BV121
YT2_ S02_ P52
nvoYTS02p052
SNVT_switch (95)
BD 50
0181
N/A
0/1
0/1
SCC Auto Detect Digit 3
N
S
S
S
S
P53
BV122
YT2_ S02_ P53
nvoYTS02p053
SNVT_switch (95)
BD 51
0182
N/A
0/1
0/1
SCC Auto Detect Digit 4
N
S
S
S
S
P54
BV123
YT2_ S02_ P54
nvoYTS02p054
SNVT_switch (95)
BD 52
0183
N/A
0/1
0/1
SCC Auto Detect Digit 5
N
S
S
S
S
P55
BV124
YT2_ S02_ P55
nvoYTS02p055
SNVT_switch (95)
BD 53
0184
N/A
0/1
0/1
SCC Auto Detect Digit 6
N
S
S
S
S
P56 MV101
YT2_ S02_ P56
nvoYTS02p056 SNVT_count_f (51) ADI 25 0130 x1 None None
Refrigerant [0=R-22, 1=R-407c, 2=R-410a, 3=R-
454B]
NSSSS
P57
MV102
YT2_ S02_ P57
nvoYTS02p057
SNVT_count_f (51)
ADI 26
0131
N
N
N
N
N
P58
MV103
YT2_ S02_ P58
nvoYTS02p058
SNVT_count_f (51)
ADI 27
0132
N
N
N
N
N
P59
MV104
YT2_ S02_ P59
nvoYTS02p059
SNVT_count_f (51)
ADI 28
0133
N
N
N
N
N
P60
MV105
YT2_ S02_ P60
nvoYTS02p060
SNVT_count_f (51)
ADI 29
0134
N
N
N
N
N
P61
MV106
YT2_ S02_ P61
nvoYTS02p061
SNVT_count_f (51)
ADI 30
0135
N
N
N
N
N
P62
MV107
YT2_ S02_ P62
nvoYTS02p062
SNVT_count_f (51)
ADI 31
0136
N
N
N
N
N
P63
MV108
YT2_ S02_ P63
nvoYTS02p063
SNVT_count_f (51)
ADI 32
0137
N
N
N
N
N
P64
MV109
YT2_ S02_ P64
nvoYTS02p064
SNVT_count_f (51)
ADI 33
0138
N
N
N
N
N
P65
MV110
YT2_ S02_ P65
nvoYTS02p065
SNVT_count_f (51)
ADI 34
0139
N
N
N
N
N
P66
AV130
YT2_ S02_ P66
nvoYTS02p066
SNVT_count_f (51)
ADF 73
0140
N
N
N
N
N
P67
AV131
YT2_ S02_ P67
nvoYTS02p067
SNVT_count_f (51)
ADF 74
0141
N
N
N
N
N
P68
AV132
YT2_ S02_ P68
nvoYTS02p068
SNVT_count_f (51)
ADF 75
0142
N
N
N
N
N
P69
AV133
YT2_ S02_ P69
nvoYTS02p069
SNVT_count_f (51)
ADF 76
0143
N
N
N
N
N
P70
AV134
YT2_ S02_ P70
nvoYTS02p070
SNVT_count_f (51)
ADF 77
0144
N
N
N
N
N
P71
AV135
YT2_ S02_ P71
nvoYTS02p071
SNVT_count_f (51)
ADF 78
0145
N
N
N
N
N
P72
AV136
YT2_ S02_ P72
nvoYTS02p072
SNVT_count_f (51)
ADF 79
0146
N
N
N
N
N
P73
AV137
YT2_ S02_ P73
nvoYTS02p073
SNVT_count_f (51)
ADF 80
0147
N
N
N
N
N
P74
AV138
YT2_ S02_ P74
nvoYTS02p074
SNVT_count_f (51)
ADF 81
0148
N
N
N
N
N
P75
AV139
YT2_ S02_ P75
nvoYTS02p075
SNVT_count_f (51)
ADF 82
0149
N
N
N
N
N
P76
AV140
YT2_ S02_ P76
nvoYTS02p076
SNVT_count_f (51)
ADF 83
0150
N
N
N
N
N
P77
AV141
YT2_ S02_ P77
nvoYTS02p077
SNVT_count_f (51)
ADF 84
0151
N
N
N
N
N
P78
AV142
YT2_ S02_ P78
nvoYTS02p078
SNVT_count_f (51)
ADF 85
0152
N
N
N
N
N
P79
AV143
YT2_ S02_ P79
nvoYTS02p079
SNVT_count_f (51)
ADF 86
0153
N
N
N
N
N
P80
BV125
YT2_ S02_ P80
nvoYTS02p080
SNVT_switch (95)
BD 54
0185
N
N
N
N
N
P81
BV126
YT2_ S02_ P81
nvoYTS02p081
SNVT_switch (95)
BD 55
0186
N
N
N
N
N
P82
BV127
YT2_ S02_ P82
nvoYTS02p082
SNVT_switch (95)
BD 56
0187
N
N
N
N
N
P83
BV128
YT2_ S02_ P83
nvoYTS02p083
SNVT_switch (95)
BD 57
0188
N
N
N
N
N
P84 BV129
YT2_ S02_ P84
nvoYTS02p084 SNVT_switch (95)
BD 58
0189
N/A
0/1 0/1 Units [0=Imperial, 1=Metric] NSSSS
1
2
3
4
5
6
7
8
9
10
BACnet engineering units shown with an Asterisk (*) will be assigned a BACnet engineering unit type of 95 - No Units.
Status codes: Special display characters such as ( ) [ ] { } / \ % < > are not compatible with eLink N2 formats. Substitute text strings "-", PCT, GTN will be used. String lengths are limited to 60 total
characters, including spaces.
LON SNVTs used: SNVT_count_f (51) and SNVT_switch (95). Must use LON eLink.
Modbus scaling factors indicated in
bold
with an asterisk (*) are user configurable by a field technician, if necessary. All Modbus values are of the type SIGNED with the exception of the user configurable
values that are all UNSIGNED. Modbus function types supported: ENG P03-P06 = Types 03, 06, 16; ENG P07-P10 = 01, 03, 05, 06, 15, 16; ENG P36-P55 & P80-84 = 01, 02, 03
Eng
Page
Ref
BACnet
Object
Typ/Ins
BACnet Object
Name
LON Profile
Name
LON SNVT Type
N2
Metasys
Engineering
Units
Point List Code: S = Standard O = Optional N = Not Available
NOTES
Modbus
Scroll BAS(ISN)
Johnson Controls, Inc.
Subject to change without notice.
5 of 6
02/11/2020