4.3 OPTION AND CHOPPER CONFIGURATION
Configuration of the model MENU SEL MODEL enables to have the chopper to work in
one of the following set:
1 Standard pump
2 Pump + Hydro = pump + hydroguide contactor
Option configuration MENU SEL OPTIONS
fucntion/pinfucntion/pin
fucntion/pinfucntion/pin
fucntion/pin
optionoption
optionoption
option
descriptiondescription
descriptiondescription
description
1)1)
1)1)
1)
PIN G3PIN G3
PIN G3PIN G3
PIN G3
bypassbypass
bypassbypass
bypass The contactor connected to connector G3 is handled as a
bypass, with activation current = 80%Imax., output current
= 90%Imax., activation delay=800 msec.
weakweak
weakweak
weak The contactor connected to connector G3 is handled as
weakening, with activation current = 50% of the programmable
output current (WEAK DROP OUT) from 10% to 100% Imax.
Activation delay=800 msec.
3)3)
3)3)
3)
BATTERYBATTERY
BATTERYBATTERY
BATTERY
freefree
freefree
free No low charge alarm.
checkcheck
checkcheck
check Activates the check that reads the battery voltage in standby.
When the residual charge is less than 10%, the maximum
current is halved and the LED blinks continuously.
6)6)
6)6)
6)
HOURSHOURS
HOURSHOURS
HOURS
runningrunning
runningrunning
running Hour-metre only active when running.
key onkey on
key onkey on
key on Hour-metre active with the key on.
4) PIN G54) PIN G5
4) PIN G54) PIN G5
4) PIN G5
statusstatus
statusstatus
status PIN G5 output is active when the chopper is executing any
function but STOP UP.
main c.main c.
main c.main c.
main c. PIN G5 output drives a general contactor
Selection of battery voltage MENU SEL BATTERY
It enables to set the nominal battery voltage to drive the charge status of the battery and the tester
functions.
Voltages to be selected: 24/36/40/48V, 60/72/80/96V
With ROLL UP and ROLL DOWN buttons it is possible to select the nominal battery voltage and
SET UP and SET DOWN buttons allow fine battery voltage adjustments.