Pagina 20
5 )5 )
5 )5 )
5 )
INCORRECT STARTINCORRECT START
INCORRECT STARTINCORRECT START
INCORRECT START
A running request is present on key startup.
Possible causes:
a) Operator error.
b) Request microswitch stuck.
6)6)
6)6)
6)
I HIGH AT STANDI HIGH AT STAND
I HIGH AT STANDI HIGH AT STAND
I HIGH AT STAND
Test carried out in standby, checks that the current is nil.
If this is not verified, an alarm is signalled. This alarm shuts down the machine. Possible causes:
a) Current sensor broken and logic failure.
First replace the logic, and if the defect persists, replace the power unit.
7)7)
7)7)
7)
I=0 EVERI=0 EVER
I=0 EVERI=0 EVER
I=0 EVER
Test carried out in running.
Checks that the current during running is greater than a minimum value. If not, an alarm is
signalled and the machine is shut down. Possible causes:
a) The current sensor is faulty. Replace the power unit.
8)8)
8)8)
8)
EEPROM PAR.KOEEPROM PAR.KO
EEPROM PAR.KOEEPROM PAR.KO
EEPROM PAR.KO
Fault in the area of memory in which the adjustment parameters are stored. This alarm
inhibits machine operation.
If the defect persists when the key is switched off and on again, replace the logic.
If the alarm disappears, remember that the parameters stored previously have been
cancelled, and replaced by the default values.
9)9)
9)9)
9)
EEPROM CONF.KOEEPROM CONF.KO
EEPROM CONF.KOEEPROM CONF.KO
EEPROM CONF.KO
Fault in the area of memory in which the special chopper configuration data is stored. If
the defect persists when the key is switched off and on again, replace the logic. Otherwise,
keep in mind that the chopper configuration has been reset to the default values
(regeneration voltage, etc.); thus it must be re-programmed. Consult the console manual.
10)10)
10)10)
10)
EEPROM DATA KOEEPROM DATA KO
EEPROM DATA KOEEPROM DATA KO
EEPROM DATA KO
The data in the area of memory that handles the hour-metre is incorrect. This alarm does
not shut down the machine. If the alarm disappears when the machine is switched off and
on again, keep in mind that the hour-metre data has been reset to zero.
11)11)
11)11)
11)
EEPROM OFF LINEEEPROM OFF LINE
EEPROM OFF LINEEEPROM OFF LINE
EEPROM OFF LINE
Fault in the non-volatile memory that contains data relative to the area for the hour-metre,
the alarms stored and the programming parameters.
If the alarm persists when the key is switched off and on again, replace the logic.
12)12)
12)12)
12)
CHOP. NO CONF.CHOP. NO CONF.
CHOP. NO CONF.CHOP. NO CONF.
CHOP. NO CONF.
An alarm similar to no.9, except that here, even though the data is correct, it does not
correspond to a hardware configuration recognised by the H2. The considerations are the
same as for alarm 9 “EEPROM CONF.KO”.
13)13)
13)13)
13)
WATCH-DOGWATCH-DOG
WATCH-DOGWATCH-DOG
WATCH-DOG
The test is made in both running and standby.
It is a self-diagnosis test within the logic.
If an alarm should occur, replace the logic.