MAINTEINANCE
Check outwear of electric contacts: they should be replaced when matchboard is
too strong and wornout. Electric contacts should be checked every 3 months.
Check pedal microswitch: verify with a tester that there is no electric resistance
between the contacts by measuring the voltage drop between its terminals. Also the
release should have a firm sound. The pedal microswitch should be checked
every 3 months.
Check motor-battery power links: they should be in excellent shae as well as the
wires' claddings. Wires should be checked every 3 months.
Control of the pedal and contactors springs. They should be able to extend to its
full extention and checked every 3 months.
Check contactors mecanical movements. They should be frictionfree and not stick.
Mechanical movements of the contactors should be checked every 3 months.
CHECKS SHOULD BE DONE BY SKILLED PERSONNEL ONLY AND, ALL SPARE PARTS SHOULD
BE
ORIGINAL.
INSTALLATION OF THIS ELECTRONIC CONTROLLER SHOULD BE DONE ACCORDING TO THE
DIAGRAMS
INCLUDED IN THIS MANUAL AND ANY VARIATION SHOULD BE DONE
ACCORDINGLY WITH THE SUPPLIER. THE SUPPLIER IS NOT RESPONSIBLE FOR ANY
PROBLEM
THAT ROSE FROM USING WIRING SOLUTIONS DIFFERENT FROM THE ONES
SUGGESTED ON THIS MANUAL.
DO NOT USE A VEHICLE WITH A
FAULTY ELECTRONIC CONTROLLER