Pagina 19
55
55
5
DIAGNOSISDIAGNOSIS
DIAGNOSISDIAGNOSIS
DIAGNOSIS
Description of the alarms signalled by the diagnostic LED.
The alarm code is shown in parentheses. A detailed description is given in the section
“DECODING THE ALARMS DISPLAYED ON CONSOLE”.
1 BLINK1 BLINK
1 BLINK1 BLINK
1 BLINK = Logic anomaly (EEPROM DATA KO, EEPROM PAR. KO, EEPROM CONF.
KO, EEPROM OFF-LINE, CHOPPER NO CONF, WATCH-DOG).
2 BLINKS2 BLINKS
2 BLINKS2 BLINKS
2 BLINKS = Running request on startup or error in handle/speeds sequence (INCORRECT \
START).
3 BLINKS3 BLINKS
3 BLINKS3 BLINKS
3 BLINKS = Error on VMN test (NO FUL CONDUCTION).
4 BLINKS4 BLINKS
4 BLINKS4 BLINKS
4 BLINKS = Accelerator high in standby - this error inhibits machine operation (VACC > 1 V).
5 BLINKS5 BLINKS
5 BLINKS5 BLINKS
5 BLINKS = Error in reading current - this error inhibits machine operation (1 HIGH AT
STAND, I=0 EVER).
6 BLINKS6 BLINKS
6 BLINKS6 BLINKS
6 BLINKS = Malfunctioning of the contactor driver circuit (DRIVER SHORTED, COIL
SHORTED).
7 BLINKS7 BLINKS
7 BLINKS7 BLINKS
7 BLINKS = Excessive temperature, greater than 80_ (TH. PROTECTION).
CONTINUOUS BLINKING (32 BLINKS)CONTINUOUS BLINKING (32 BLINKS)
CONTINUOUS BLINKING (32 BLINKS)CONTINUOUS BLINKING (32 BLINKS)
CONTINUOUS BLINKING (32 BLINKS) =Low battery charge, battery with < 10% of
residual charge (BATTERY).
5.15.1
5.15.1
5.1
DECODING THE ALARMS DISPLAYED ON CONSOLEDECODING THE ALARMS DISPLAYED ON CONSOLE
DECODING THE ALARMS DISPLAYED ON CONSOLEDECODING THE ALARMS DISPLAYED ON CONSOLE
DECODING THE ALARMS DISPLAYED ON CONSOLE
1)1)
1)1)
1)
STAND BY VMN LOWSTAND BY VMN LOW
STAND BY VMN LOWSTAND BY VMN LOW
STAND BY VMN LOW
The test is carried out in standby. If the VMN voltage is lower than 1/3 of the battery
voltage, an alarm is signalled. Possible causes:
a) Check the motor wiring to make sure it is correct.
b) Chopper broken, replace.
2)2)
2)2)
2)
NO FULL COND.NO FULL COND.
NO FULL COND.NO FULL COND.
NO FULL COND.
The test is carried out in full conduction.
If, in this condition, the VMN is found to be greater than 1/3 VBATT, the diagnostic
circuit is faulty, causing a safety risk, and thus machine operation is inhibited. If the defect
persists, replace the logic.
3)3)
3)3)
3)
TH.PROTECTIONTH.PROTECTION
TH.PROTECTIONTH.PROTECTION
TH.PROTECTION
An indication that the chopper temperature has exceeded 80°C.
The maximum current is gradually reduced, reaching 0 at a temperature of 85°C. If the
alarm occurs while cold:
a) Check the thermal sensor connection.
b) Thermal sensor failure.
c) Connection on the power interrupted (check the connector that connects the logic to
the power unit).
d) Logic failure.
4)4)
4)4)
4)
BATTERYBATTERY
BATTERYBATTERY
BATTERY
The battery charge is low.
The alarm is signalled only if the BATTERY CHECK option has been selected. All
functions except hydrdrive are inhibited.