41
9,Weather resistance test
measured by sunshine meter 75 hours.
10,Corrosion resistance test
Exposed to 5% saline solution at 35 96 hours.
11,Water pressure resistance test
98 N/cm
2
for 20min
0 N/cm
2
for 1min
100 cycles underwater N/cm
2
0 N/cm
2
4. Quality Assurance Standards
54-1. Inspection Methods
Acceptable quality levels are determined as described below.
An acceptable quality level is defined as the quality level used during acceptance inspections to
determine whether a lot is defective or non defective.
It is agreed that such acceptance inspections will be performed by your company on our company’s
products immediately after they are delivered, and that your company will provide per lot notification of
the inspection results.
Inspection method
Sampling inspection level 2, under MILSTD-105D “Sampling procedures and Table for Inspection by
Attributes”.
98
1 cycle
20min
1min