EasyManua.ls Logo

Zeagle N2ition - Technical Specifications; Accuracy and Measurement Ranges; Operating Temperature and NITROX Settings; Water Resistance and Battery Life

Zeagle N2ition
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
1-4.Technical Specifications
(1)Accuracy
Time: average monthly variance ±30 seconds
Depth: ±3%+0.5m(±3%+2ft)
Temperature : ±2.0(±4°F)
(2)Measurement range
Depth: 0.0-99.9m(0.0-328ft) /In gage mode, 0.0-199.9m(0.0-656ft)
(Uses saltwater as standard)
Dive time: 0-599 minutes
Altitude: 0-6000m(0-19680ft)
Measurement interval of 10 minute
(It excludes dive mode, time set mode, PC transfer mode.)
Temperature: -5+40(23104°F)
Measurement interval of 1 minute (measures only in Dive mode)
(3)Operating temperature
Operating temperature: -5+40(23104°F)
(At cold temperature, the display will be somewhat dim)
(4)NITROX setting
MIX1 FO
2
:21-50%, setting step: 1%
MIX2 FO
2
:21-99%, setting step: 1%
(5)waterproof ability
The waterproof ability: to 99.9m(328ft)
(6)Battery life
Battery life: about 3 years (uses battery CR2032) under conditions as follows:
The computer is used for 50 one-hour dives in a year, with the alarm sounding for 10 seconds per a
dive, with the EL backlight for 10 seconds per a dive.

Related product manuals