11
• Dive time alarm: The alarm generates to sound when it reaches diving time.
The setting range: 10-590 minutes,resolution:10 minute.
• Nitrox Icon: This Icon is ON when NITROX has been set for MIX1 or MIX2.It blinks if the MIX1 and
MIX2 setting is the default setting.
• Sea/Fresh Icon: This indicates the water setting (sea water/fresh water).
• Gage Mode Icon: In gage mode, the icon is on.
• Mode display: This shows Dive set mode.
(2)Operation of switches
• A: Press this switch to select place you want to change.
GAGE SELECT→MIX1 FO
2
set→MIX2 FO
2
set→User Safety Factor→Profile time→Sea/Fresh→MAX DEPTH
SET→MAX DEPTH ALARM ON/OFF→DIVE TIME SET→DIVE TIME ALARM ON/OFF→GAGE
SELECT→………
<Caution>
In PGT, OLI, DESAT, the SURF.T count, it isn't possible to do GAGE SELECT choice.
Also, when MIX1 isn't set ( the ‘--’% display ), it isn't possible to do the setting of MIX2.
• B: Press this switch to move to dive plan mode .
(In gage mode, press this switch to move to dive log mode.)
• C: Press this switch to change setting the contents.
• C: Press and hold this switch to change setting the contents fast scrolling.
• D: When water is detected, the mode moves to dive mode.
• Auto return: The display automatically returns to time mode when no switches are used for 2-3
minutes.
• B: Press and hold this switch for 1-2 seconds to move to time mode.
1-3-3.Dive plan mode
It cannot enter in gage mode.
Caution
“--”% display:The setting switches to these values automatically at 24:00 on the day when
the value is set all value, except the setting of Air (FO
2
: 21%).
If user forgets to set, alarm is generated when the mode moves to dive mode.
If MIX1 is set 21% and when MIX2 is set 21% or “--”%, The MIX1 setting is not changed.
The MIX2 setting is always changed to “--”% at 24:00 on the day.