Communications Diagnostics
12/23/10 GK888t™ User Guide P1030829-001
The following example of a communications DUMP mode printed out. The printout displays
hexadecimal data 00h-FFh (0-255 decimal) with a unique character for each hexadecimal
value displayed above the hexadecimal data.
The blank lines between the lines of data are where serial port and Bluetooth data handling
errors get logged. The errors are:
•F = Frame Error
P = Parity Error
•N = Noise Error
O = Data Overrun Error
To exit the diagnostic mode and resume printing, turn off and then turn on the printer. An
alternate method for exiting the diagnostic mode is to press the Feed button as many times as it
takes to clear the printers command buffer and print ‘Out of DUMP’ on the label.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra GK888t and is the answer not in the manual?

Zebra GK888t Specifications

General IconGeneral
Print MethodThermal Transfer and Direct Thermal
Resolution203 dpi (8 dots/mm)
Maximum Print Width4.09 inches (104 mm)
Memory8 MB Flash
ConnectivityUSB, Serial, Parallel
Media SensorsReflective and transmissive
Media HandlingRoll-to-roll, fanfold, tag stock
Media Typestag stock
Ribbon Ratio1:1
Programming LanguagesEPL2, ZPL
Power Requirements2.5A
Storage Temperature-40° F to 140° F/-40° C to 60° C
Humidity20 to 85% non-condensing