Resetting the Factory Default Values
82
P1030829-001 GK888t™ User Guide 12/23/10
Resetting the Factory Default Values
Sometimes, resetting the printer to the factory defaults may solve some problems. Refer to the
four-flash sequence in Feed Button Modes on page 84 in this section.
Communications Diagnostics
If there is a problem transferring data between the computer and printer, try putting the printer
in the communications diagnostics mode. The printer will print the ASCII characters and their
respective hexadecimal values (a sample is shown below) for any data received from the host
computer. To find out how,
There are multiple ways to enter hex data dump mode:
•The ~JD ZPL command
•The dump EPL command
On power up with the Feed button pressed. Refer to the power off mode procedure in Feed
Button Modes on page 84 in this section.
The printer will print ‘Now in DUMP’ (see below) and advance to the top of the next label.