Page 14 of 28 801314 v3.05 09.20 HT BC Commercial Instructions
Booster Installation
3.2 Installation Procedure
Site requirements
The appliance must only be installed in a frost-free area. Never expose the appliance to frost.
The appliance is designed for wall mounted installation and must to be installed with water connectors
facing upwards.
The appliance complies with protection class IP 25.
The 400mm braided hoses supplied with the Command Centre cannot be lengthened.
The 90° elbow hose ends should be fitted to the inlet and outlet connections on top of the Booster.
The hot water outlet hose must be thermally insulated with the insulation provided.
Tilt Forward Lift UP
Release
NoteNote: Remove the backing plate for wall mounting
3.3 To Remove / Install the appliance
1. Insert a flat head screwdriver all the way into the lock.
2. Gently angle the screwdriver upwards by approximately 10° as shown in the image below.
3. Pull the appliance forwards by approximately 15° as shown.
4. Carefully pull the appliance upwards to complete the removal process, taking care not to break the
lower clips
5. To install: place the appliance on the wall bracket and snap into position (see illustration below).
Take care not
to break the
lower clips when
removing or
installing the
Booster
!