801314 v3.05 09.20 HT BC Commercial Instructions Page 13 of 28
Booster Specifications:
Rating Unit
Nominal Power Rating 2.2 kW
Nominal Current 10 A
Electric Supply 50Hz AC 230 V
Elect ex and plug (black) - 1 metre length (with 90º Australian plug) 10 A
Fixed Flow Rate 1.2 L/min
Minimum water pressure 200 kPa
Section 3
Booster Heater
Mount base
Horizontally
3.1 Product Description
The boost unit is a compact electronically
controlled auxiliary water heater. It is intended to
provide pre heating of water before it enters the
Zip HydroTap G4 boiling tank. The Booster is
supplied as standard equipment with all 240 cup
models. However, it may be later installed, as an
accessory for the 160 cup models, to increase
their delivery to 240 cups.
400mm
NoteNote 1: water connection
Blue marking: water in
Red marking: water out.
The braided hoses cannot be length-
ened.
NoteNote 2: The electrical cable length
is 1.0 metre.
NoteNote 3: Position the Booster within
reach of the fixed hose lengths, keep-
ing the Booster as close as possible
to the Command Centre inlet/ outlet
fittings.
NoteNote 4: Ensure the Booster heater
is mounted in an upright position (as
shown) with a horizontal base.