3.2.1 Chlorine produc on ac vated
When chlorine produc on starts, the "Start..." message is displayed on screen for about 6 seconds. "CHLORINATION" is
then displayed, indica ng that the appliance is producing chlorine.
3.2.2 "BOOST" mode: chlorine produc on increased to 100 % for 24 h
In certain cases the pool may need higher than normal chlorina on (stormy weather, high number of bathers, etc.).
"BOOST" mode is used to increase chlorine level quickly.
Press bu ons
and simultaneously: "BOOST" is displayed on the screen and 100 % chlorine produc on
starts.
To stop "BOOST" mode, press
.
When "BOOST" mode is ac vated, the rated chlorine produc on se ngs are temporarily overridden and the
Ei² Expert chlorinator will operate for a total of 24 hours at 100 % chlorine produc on. The number of days will
therefore depend on the Ei² Expert opera ng mes (see “3.2.5 “SUMMER” and “WINTER” modes and se ng
the “Timers””).
3.2.3 "LOW" mode: chlorine produc on reduced to 10 % if the pool is covered
If the pool has a covering system (shelter, shu er, cover, etc.), "LOW" mode is designed to adapt chlorine produc on to
situa ons where the pool is covered (lower needs). Its purpose is to limit chlorine produc on to 10%.
If chlorina on is set to 0% when closing the shu er, "LOW" mode will keep the 0% se ng.
This mode is also called "Shu er" mode.
Manual ac va on (shelter, cover, etc.):
Press bu ons
and simultaneously: "LOW" is displayed on the screen and chlorine produc on is reduced
to 10 %.
To stop "LOW" mode, press
.
Automa c ac va on (compa ble with an electric roller shu er):
Make sure the cover is compa ble and connected to the chlorinator (see “2.5.2 Connec on to an electric roller shu er”).
"LOW" mode will automa cally be ac vated when the shu er is closed.
"LOW" mode will stop as soon as the shu er is completely open.
3.2.4 Se ng the  me
The Ei² Expert chlorinator is ed with an internal memory. When the appliance is rst switched on, it is
important to leave it powered on con nuously for at least 24 hours in order to ini ally charge the accumulator
(permanent separate power supply or ltering on permanently). Once charged, the accumulator has several
weeks of autonomy in the event of a power failure.
The  me is displayed in 24-hour format.
Switch on the appliance and wait un l the screen start-up sequence is  nished.
Press the bu on to access the user menu, the minutes will start to fl ash.
Use the and bu ons to set the minutes, then press to save.
Use the and bu ons to set the hours, then press to save.
Press the bu on to return to the home screen.