23
5.2 I Error code display
Display Fault Possible causes Soluons
A11
Low-pressure fault
- circuit 1
A13
Low-pressure fault
- circuit 2
No signal from the low-pressure
switch
Defecve pressure switch, replace if
necessary
Leak in the cooling circuit Call a qualied technician.
Blocked evaporator, air ow too
low
Remove any dirt or obstacles from the
evaporator blocking the air ow
Frost on the evaporator
Check that the 4-way valve is
operang correctly
Fan operaon problem
Check that the fan is operang
correctly, replace it if necessary
Regulator valve closed
Defecve regulator (or its
controller), replace if necessary.
A12
High-pressure fault
- circuit 1
A14
High-pressure fault
- circuit 1
No signal from the high pressure
switch
Defecve pressure switch, replace if
necessary
Insucient water ow
Increase ow using the by-pass,
check that the pool lter is not clogged
Cooling circuit fault
Check the cooling circuit
A15
Water ow
controller
Water ow problem
• Check that the ow rate is sucient
• Check that the pump is working
• Check the ow switch
A21
Water inlet
temperature
sensor fault
Sensor is faulty or oine
Reconnect or change the sensor
A22
Evaporaon
sensor 1 fault
Sensor is faulty or oine
Reconnect or change the sensor
A23
Evaporaon
sensor 2 fault
Sensor is faulty or oine
Reconnect or change the sensor
A24
Compressor 1
discharge sensor
fault
Sensor is faulty or oine
Reconnect or change the sensor
Discharge temperature too high
A25
Compressor 2
discharge sensor
fault
Sensor is faulty or oine
Reconnect or change the sensor
Discharge temperature too high
A26
A26
Circuit 1 sucon
sensor fault
Sensor is faulty or oine
Reconnect or change the sensor
A27
A27
Circuit 2 sucon
sensor fault
Sensor is faulty or oine
Reconnect or change the sensor
A28
Outside air
temperature
sensor fault
Sensor is faulty or oine
Reconnect or change the sensor
A29
Water outlet
temperature
sensor fault
Sensor is faulty or oine
Reconnect or change the sensor