ZONEMASTER MAXIPOINT V2 DAMPER CONTROL SYSTEM - Installation Manual
2
1) Application
The Zonemaster MaxiPoint V 2 control system is a fully featured and
engineeredsystemthatisdesignedtomanagetheairowfromtheA/C
Unitprovidingabalancedandmanagedairowtoalloutlets.Itiswell
suited to all ducted reverse cycle, ducted heating and evaporative air
conditioning systems in light commercial, residential and apartment
applications.
2) Features
• Supportsupto16individual zones (Zone 1, 2…9, A, B…G), 16 groups
(Group 1, 2…9, A, B…G) with maximum of 4 zones in a group.
• Dampers are connected directly to the main control module or its
extension module.
• Wallmountedtouchpad(s)withupto4touchpadsavailablein
a system.
• Manualandtimeprogrammablegroupon/offcontrol.
• LCDonthetouchpadsforgroupstatusandparameterdisplay.
• Personalisedgrouplabelling.
• 5-1-1programmableon/offtimeprograms.
• Remotezonebalancing---eachzone’sopeningpositioncanbe
programmedforbalancingpurposeviatouchpadfrom0-100%.
• Oneselectableturbogroup.
• Autospill/bypass(dedicatedbypasszoneport)---thedesignated
zone dampers are forced open when all zones are turned off.
• Safetysystem---Opensalldampersifthesupplyairtemperature
reaches low or high limit.
• All zones automatically resume their original on/off state once power
up after power outage.
• Halfyearly (182 days) and Two yearly (728 days) service alerts remind
customers to call technician for cleaning and air conditioning system
service respectively.
• 24volts for easy and safe installation and maintenance.