2). Transmission of FlashSys (TX) master side
In the state that “LCD displays [System Update All: SYS Patch: STO]”, push
[AMP SELECT/SYSTEM] key.
Then LCD displays [Sending all… FullChip erase..] and [Sending all…] in a row.
And transmission of FlashSys starts. After transmission completes, LCD displays
[Sending all… Done…], then return to former display. And, it is possible to
transmit any number of times by pushing the key again.
In addition, there are no ways to finish without power down if operation is
completed correctly,
*About Error display
If writing is not completed correctly, following error message is displayed of the
LCD.
Message 1 : Slave timeouted.
Contents: Equipments are not connected.
Measure: Make sure connection correctry between equipments.
Message 2 : Invalid slave
Contents: Transmission has been done between difference equipments.
Measure: Make sure whether connected equipments are the same ones.
Message 3 : erase timeouted
Contents: Failure of block erasing.
Measure: Make sure whether the unit of writing side is normal.
Message 4 : Error on erase
Contents: All area hasn’t been erased.
Measure: Make sure whether the unit of writing side is normal.
Message 5 : Error on trans.
Contents: Writing hasn’t completed correctly.
Measure: Make sure whether the unit of writing side is normal.
-25-