ZXR10ZSRV2CongurationGuide(SystemManagement)
different.Thedevicecomparesthetemperatureinformationobtainedatspecied
timewiththecorrespondingalarmthreshold.Ifthetemperatureexceedsthe
threshold,thealarmisreported.Ifthetemperatureislowerthanthethreshold,the
alarmatthecorrespondingleveliscleared.
lPowerVoltageAlarm
Ifthevoltagerangenotinthenormalworkingvoltagerange,thepowervoltagealarm
isreported.
7.2ConguringtheAlarmFunction
Thisproceduredescribeshowtocongurethealarmfunction.
Steps
1.Congurethebasicalarmfunction.
StepCommandFunction
1ZXR10(config)#loggingonEnablesthealarmrecordingfunction,
sothatalarmscanbereportedtolog,
controlterminal,SNMP ,andSYSLOG.
2ZXR10(config)#loggingbuffer<buffer-size>Setsthesizeofthealarmlogbuffer.
Unit:KB,range:100–1000,default:
200.
3ZXR10(config)#loggingtimestamps[datetime
localtime|precisetime|uptime]
Setsthedisplaymodeofalarmtime.
Default:datetimelocaltime.
4ZXR10(config)#logginglevel<level>Congurestheleveltosavealarms
intologs.Alarmswhoselevelsare
higherthanthislevelarerecordedin
logs.
Default:INFORMATIONAL(level7).
5ZXR10(config)#loggingconsole<level>Congurestheleveltodisplayalarms
onaconsoleorT elnetterminal.
Alarmswhoselevelsarehigherthan
thislevelaredisplayedonaconsole
orT elnetterminal.
Default:NOTIFICATIONS(level6).
6ZXR10(config)#loggingTrap-enable<level>Congurestheleveltoreportalarms
toSNMPinTrapmode.Alarmswhose
levelsarehigherthanthislevelare
reportedtoSNMPinTrapmode.By
default,alarmsarenotreported.
7-2
SJ-20140504150128-007|2014-05-10(R1.0)ZTEProprietaryandCondential