Chapter 60 MAINTENANCE
XMG1915 Series User’s Guide
367
After the process is complete, see the DASHBOARD screen to verify your current firmware version 
number.
60.15  Reboot System
Reboot System allows you to restart the Switch without physically turning the power off. It also allows you 
to load configuration one (Config 1), configuration two (Config 2), a Custom Default or the Factory 
Default configuration when you reboot. Follow the steps below to reboot the Switch.
Click MAINTENANCE > Reboot System to view the screen as shown next.
Figure 268   MAINTENANCE > Reboot System
1 Click the Config 1, Config 2, Factory Default, or Custom Default button to reboot and load that 
configuration file. The confirmation screen displays.
Table 205   MAINTENANCE > Firmware Upgrade
LABEL DESCRIPTION
Name This is the name of the Switch that you are configuring.
Version The Switch has 2 firmware sets, Firmware 1 and Firmware 2, residing in flash.
• Running shows the version number (and model code) and MM/DD/YYYY creation date 
of the firmware currently in use on the Switch (Firmware 1 or Firmware 2). The firmware 
information is also displayed at System Information in Basic Setting.
• Firmware 1 shows its version number (and model code) and MM/DD/YYYY creation 
date.
• Firmware 2 shows its version number (and model code) and MM/DD/YYYY creation 
date.
Boot Image
Current Boot Image This displays which firmware is currently in use on the Switch (Firmware 1 or Firmware 2).
Config Boot Image Select which firmware (Firmware 1 or Firmware 2) should load, click Apply and reboot the 
Switch to see changes, you will also see changes in the Current Boot Image field above as 
well.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these 
changes if it is turned off or loses power, so use the Save link on the top navigation panel to 
save your changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.
Firmware Choose to upload the new firmware to (Firmware) 1 or (Firmware) 2.
File Path Click Choose File or Browse to locate the firmware file you wish to upload to the Switch.
Upgrade Click Upgrade to load the new firmware. Firmwares are only applied after a reboot. To 
reboot, go to MAINTENANCE > Reboot System and click Config 1, Config 2 or Factory 
Default (Config 1, Config 2, Factory Default, and Custom Default are the configuration files 
you want the Switch to use when it restarts).