PCManager Use – Basic
The main purpose of PCManager UNI is to set configuration and upgrade firmware of
EasyGate.
When the EasyGate configuration is to be changed, the configuration must be first loaded
from EasyGate, then edited using PCManager and finally saved back to EasyGate.
The parameter groups are listed in the left window of the program. All the parameters are
described in the next part of this manual. There is an interactive help in PCManager for all
the parameters.
When you start any operation that needs communication with EasyGate, the gateway
must be switched to a special programming mode. PCManager will show you the demand
to switch the gateway off and on to set it to this mode.
Further Data Handling Options
In addition to the EasyGate memory, settings can be saved in a PC file and reloaded into
PCManager. This is recommended for backing up current configurations or saving the same
configuration to another Easy Gate unit.
Caution
The Security table includes the PIN code and service password. These parameters
have a special handling. They are not saved in a PC file for security reasons. If you
load a PC file into PCManager UNI and then into EasyGate, the PIN and service
password should not change unless you change them manually before saving.
Caution
All the tables are filled-in with default values when PCManager UNI starts. It is
recommended to load data from EasyGate before programming and saving the
parameters. If you only save data after the PCManager UNI start, all the parameters
except the PIN and service password in the EasyGate memory will have their
default values.

Other manuals for 2N EasyGate Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2N EasyGate Pro and is the answer not in the manual?

2N EasyGate Pro Specifications

General IconGeneral
MountingDIN-rail
Device typeCellular network gateway
Built-in displayNo
Market positioningBusiness
Data networkGSM
SIM interface3 V
GSM bands supported850, 900, 1800, 1900 MHz
USB portYes
USB 2.0 ports quantity1
Antenna connector typeSMA
Input voltage100 - 240 V
Operating temperature (T-T)0 - 45 °C
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)163 x 157 x 38 mm

Related product manuals