5.5.3 Camera
This menu is only available in the2N IP intercommodels that are equipped with an internal
camera or can be connected to an external camera. The camera signal can be streamed directly
into the call via a videophone, sent by E-mail, streamed via ONVIF/RTSP to another device (a
video surveillance device, e.g.), or simply HTTP downloaded from the intercom in the JPEG
format.
The following video signal sources can be used:
an internal integrated camera or external analogcamera (2N
®
IP Video Kitonly)
a standard external IP camera supporting RTSP stream with codecs MJPEG (640 x 480 max
resolution) or H.264 (640 x 480 Base Line Profile max resolution). The recommended
framerate is 15 frames per second in either case. Higher frame rates may result in
undesired effects (less smooth playing).
TheCamera menu helps you set such camera parameters as brightness, color saturation and
external IP camera login data if necessary. Refer to theServices /Phone, Services
/StreamingandServices/E-Mailmenus for the video call/streaming parameters.
Common Settings
Default Video Source – set the default video signal source. Choose Internal camera (or an
analogcamera connected to the intercom) or External IP camera. Thechange of the
default video signal source is applied to the RTSP stream and HTTP API. In 2N
®
IP Eyeit is
required to enable the external camera manually, even when there is no internal camera