Page 122 01/2007 AMT/PTD/PBX/0020/2/4/EN
6.2.4 Switch settings
Automatic resynchronization switch
CA1.2 = ON -> Automatic resynchronization
CA1.2 = OFF -> LDS operation without automatic resynchronization
Remote power supply configuration straps
J1 set to 1-2 = Remote power supply ON
J2 set to 1-2 = Remote power supply ON
J1 set to 2-3 = Remote power supply OFF
J2 set to 2-3 = Remote power supply OFF
J1: - 48 V or - 40 V
J2: +48 V or +40 V
The two jumpers must be positioned on the same side: 1-2 or 2-3.
DECT configuration switches
CA1.1 = ON -> Slave mode
CA1.1 = OFF -> Master mode