EasyManua.ls Logo

Aastra NeXspan 500 - Description of S;T Connectors of UCT-S, UCTS-12 and UCT-C Cards; Configuring the Remote Power Supply of S;T0 to S;T3 Accesses

Aastra NeXspan 500
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AMT/PTD/PBX/0020/2/4/EN 01/2007 Page 89
4.7.4 Description of S/T connectors of UCT-S, UCTS-12 and UCT-C
cards
Table 21: Pinout of S/T connectors on UCT-S, UCTS-12 and UCT-C cards
Note:
The default pinout is set to connect T0 accesses directly (straight cable). A twisted cable or T0/
S0 adaptor is required to connect DECT base stations.
4.7.5 Configuring the remote power supply of S/T0 to S/T3 accesses
UCT-S, UCTS-12 and UCT-C cards have 4 jumpers for configuring the remote power supply of
the S/T0 to S/T3 accesses (one jumper block for each access). The jumpers are plugged into
connectors J29 and J30 on the front of the UCT-S, UCTS-12 and UCT-C cards. The 4 accesses
are arranged vertically on the card. The one at the bottom is the S/T0 access and the one at the
top the S/T3 access. Depending on the position of the jumpers, the S/T0 to S/T3 accesses will
be configured as follows:
No remote power supply
48 V power supply (DECT and S sets)
40 V power supply (option)
Pin no. S/T3 S/T2 S/T1 S/T0
1
2
3
4
5
6
7
8
NC
NC
ED3
RD3
NRD3
NED3
NC
NC
NC
NC
ED2
RD2
NRD2
NED2
NC
NC
NC
NC
ED1
RD1
NRD1
NED1
NC
NC
NC
NC
ED0
RD0
NRD0
NED0
NC
NC
1
8